Gicam weight indicators are weight indicator devices connected to load cells. We have multifunction displayers for weighing and dosing, for bridge weighing, with load limiter. Portable displayers are available in comfortable briefcases. We have panel mounting, portable, DIN and OMEGA bar mounts, analog indicators and touch screens indicators. IP65 products are available with dust protection. Gicam indicators support industrial communication protocols like PROFIBUS, PROFINET, MODBUS and more.
LOAD LIMITER for load cells
Click to enlarge image
Power supply | 230 V ac (optional 115 V ac e 24 V cc) – 50 / 60 Hz | |
Max power consumption | 10 W | |
Operating temperature | -10 / +40°C (14 °F / 104°F) Humidity maximum 85% non-condensing | |
Storage temperature | -20 / +50°C (-4 / +122°F) | |
Display | High efficiency 6-digit numerical LED and wide viewing angle, reading distance up to 50 feet | |
Visualized data | Weight acquired from cells or analogue input 0-10V/4-20 mA, alphanumeric indications/programming menu | |
Overall dimensions | 320 x 110 x 90 mm /12.6 x 4.3 x 3.5 in (l x h x p) | |
Mounting | Wall-mounted with 4 external side holes Ø 6 mm with center distance 340 x 80 mm (l x h) | |
Protection level | IP 65 | |
Connections | Waterproof circular connectors with conductor wiring with screw terminal | |
Power supply load cells | 5 V dc / 120 mA (maximum 8 cells with 350 Ω in parallel) protected against short-circuit | |
Linearity | < 0.01% of full scale | |
Temperature deviation | <0,0003% of full scale/°C | |
Internal resolution | 24 bit | |
Weight resolution | Up to 60,000 divisions on useful capacity | |
Measuring range | From -1.5 mV/V to +3.5 mV/V | |
Weight acquisition frequency | 6 Hz – 25 Hz | |
Digital filter | 0,2 Hz – 25 Hz | |
Number of weight decimals | From 0 to 3 decimals | |
Logical output | 3 relays (changeover contact) maximum 115 V alternating current / 30 V direct current, 0.5 A each | |
Communication ports | RS232c / RS485 standard; 4-key remote control for configuration and operational commands | |
Max. cable length | 15 m (Rs232c), 1000 m (Rs422 + Rs485) | |
Serial protocols | ASCII + custom protocols | |
Baud rate | 1200 - 115000 bit/s, selectable | |
Options | External 868 MHz RF interface, Ethernet protocol, Profibus protocol | |
Conforms to standards | EN61000-6-2, EN6100-6-3, EN61010-1 |
Type | J1 5 poles serial female |
Length | ND |
1 | GND + Shield |
2 | RS232 Rx |
3 | RS485 - |
4 | RS485 + |
5 | RS232 Tx |
Type | J2 5 poles male load cell |
Length | ND |
1 | + Exc. Load cell |
2 | + signal load cell |
3 | - Signal load cell |
4 | - Exc. Load cell |
5 | Shield |
Type | J3 7 poles male optional outputs |
Length | ND |
1 | Out 1 NA |
2 | Out 1 NC |
3 | Out 2 NA |
4 | Out 2 NC |
5 | Out 3 NA |
6 | Out 3 NC |
7 | Common output |
General precautions to be followed in the installation and assembly of load cells: